show selftest
Syntax
show selftest [brief] [vsx-peer] show selftest line-module show selftest line-module interface [brief] [vsx-peer] show selftest interface [ ] [vsx-peer]
For 8400 and 6400 switches only:
show selftest {line-module | fabric-module} [ ] [brief] [vsx-peer]
Description
Displays selftest results.
Command context
Manager (#
)
Parameters
-
[brief]
- Shows the selftest results as a brief description. Default.
-
line-module
-
Shows the selftest results for a line module.
-
fabric-module
-
Shows the selftest results for a fabric module. Applicable only for 8400 and 6400 switches.
-
- Shows the selftest results for the slot ID of the line or fabric module.
-
- Shows the selftest results for the port number.
-
[vsx-peer]
-
Shows the output from the VSX peer switch. If the switches do not have the VSX configuration or the ISL is down, the output from the VSX peer switch is not displayed.
Authority
Operators or Administrators or local user group members with execution rights for this command. Operators can execute this command from the operator context (>) only.
Examples
Displaying the output when fastboot is disabled on an 8400 or a 6400 switch:
switch#show selftest名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- ---------- ------------------- LineModule 1/1 passed 0x0 2016-10-15 10:10:09 LineModule 1/2 failed 0x09 2016-10-15 10:10:56 Fabric 1/1 passed 0x0 2016-10-15 10:10:09 Fabric 1/2 failed 0x1E 2016-10-15 10:10:56 switch#show selftest line-module名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- --------- ------------------- LineModule 1/1 passed 0x0 2016-10-15 10:10:09 LineModule 1/2 failed 0x09 2016-10-15 10:10:56 switch#show selftest fabric-moduleName Id Status ErrorCode LastRunTime ------ -------- -------------- --------- ------------------- Fabric 1/1 passed 0x0 2016-10-15 10:10:09 Fabric 1/2 failed 0x1E 2016-10-15 10:10:56 switch#show selftest fabric-module 1/2Name Id Status ErrorCode LastRunTime ------ -------- -------------- --------- ------------------- Fabric 1/2 failed 0x11 2016-10-15 10:10:56 switch#show selftest line-module 1/10名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- --------- ------------------- LineModule 1/10 failed 0x1A 2016-10-15 10:10:56 switch#show selftest interface 1/2/2Name Status ErrorCode LastRunTime ------- -------------- --------- ------------------- 1/2/2 passed 0x0 2016-11-19 05:10:11 switch#show selftest line-module 1/3 interfaceName Status ErrorCode LastRunTime ------- -------------- --------- ------------------- 1/3/1 passed 0x0 2016-11-19 05:10:11 1/3/2 passed 0x0 2016-11-19 05:10:11 1/3/3 passed 0x0 2016-11-19 05:10:11 1/3/31 failed 0x20 2016-11-19 05:10:11
Displaying the output when fastboot is disabled on an 8320 or a 6300 switch:
switch#show selftest interfaceName Status ErrorCode LastRunTime ---------- ----------------- ---------------- ------------------- 1/1/2 skipped 0x0 1/1/44 skipped 0x0 1/1/46 skipped 0x0 switch# showselftest interface 1/1/1Name Status ErrorCode LastRunTime ---------- ----------------- ---------------- ------------------- 1/1/1 skipped 0x0
Displaying the output when fastboot is enabled on a 6400 switch:
switch#show selftest名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- ---------- ------------------- LineModule 1/1 passed 0x0 LineModule 1/2 passed 0x0 Fabric 1/1 passed 0x0 Fabric 1/2 passed 0x0 switch#show selftest line-module名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- --------- ------------------- LineModule 1/1 passed 0x0 LineModule 1/2 passed 0x0 switch#show selftest fabric-module名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- ---------- ------------------- Fabric 1/1 passed 0x0 Fabric 1/2 passed 0x0 switch#show selftest fabric-module 1/2Name Id Status ErrorCode LastRunTime ------ -------- -------------- --------- ------------------- Fabric 1/2 passed 0x0 switch#show selftest line-module 1/1名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- --------- ------------------- LineModule 1/1 passed 0x0
Displaying the output when fastboot is enabled:
switch#show selftest interface 1/1/2Name Status ErrorCode LastRunTime ------- -------------- --------- ------------------- 1/1/2 skipped 0x0 switch#show selftest line-module 1/1 interfaceName Status ErrorCode LastRunTime ------- -------------- --------- ------------------- 1/1/1 skipped 0x0 1/1/2 skipped 0x0 1/1/3 skipped 0x0 1/1/31 skipped 0x0
Displaying the output when fastboot is disabled:
switch#show selftest名字ErrorCode LastRunTime Id状态 ---------- ---- -------------- ---------- ------------------- LineModule 1/1 passed 0x0 2018-02-16 18:15:53