boot management-module
Syntax
boot management-module {active | standby | }
Description
Reboots the specified management module. Choose the management module to reboot by role (active or standby) or by slot number.
Command context
Manager (#
)
Parameters
-
active
-
Selects the active management module.
-
standby
-
Selects the standby management module.
-
-
Specifies the member and slot of the management module in the format
member/slot
. For example, to specify the module in member 1 slot 5, enter1/5
.
Authority
Administrators or local user group members with execution rights for this command.
Usage
This command is supported on switches that have multiple management modules.
This command reboots a single management module in a chassis. Choose the management module to reboot by role (active or standby) or by slot number.
You can use theshow images
command to show information about the primary and secondary system images.
If you reboot the active management module and the standby management module is available, the active management module reboots and the standby management module becomes the active management module.
If you reboot the active management module and the standby management module is not available, you are warned, you are prompted to save the configuration, and you are prompted to confirm the operation.
If you reboot the standby management module, the standby management module reboots and remains the standby management module.
If you attempt to reboot a management module that is not available, theboot
command is aborted.
Saving the configuration is not required. However, if you attempt to save the configuration and there is an error during the save operation, theboot
command is aborted.
Hewlett Packard Enterpriserecommends that you use theboot management-module
command instead of pressing the module reset button to reboot a management module because if you are rebooting the only available management module, theboot management-module
command enables you to save the configuration, cancel the reboot, or both.
Examples
当圣重启活动管理模块andby management module is available:
switch#boot management-module activeThe management-module in slot 1/5 is going down for reboot now.
当圣重启活动管理模块andby management module is not available:
switch#boot management-module 1/5The management module in slot 1/5 is currently active and no standby management module was found. This will reboot the entire switch. Do you want to save the current configuration (y/n)?nThis will reboot the entire switch and render it unavailable until the process is complete. Continue (y/n)?yThe system is going down for reboot.