show environment fan
Syntax
show environment fanis not available for JL679A.
show environment fan[vsf]
Description
Shows the status information for all fans and fan trays (if present) in the system.
Command context
Manager (#
)
Parameters
-
vsf
-
粘胶短纤的显示输出开关th会员号码at support VSF.
Authority
Operators or Administrators or local user group members with execution rights for this command. Operators can execute this command from the operator context (>) only.
Usage
For fan trays,Status
is one of the following values:
-
ready
-
The fan tray is operating normally.
-
fault
-
The fan tray is in a fault event. The status of the fan tray does not indicate the status of fans.
-
empty
-
The fan tray is not installed in the system.
For fans:
- Speed
-
Indicates the relative speed of the fan based on the nominal speed range of the fan. Values are:
-
Slow
-
The fan is running at less than 25% of its maximum speed.
-
Normal
-
The fan is running at 25-49% of its maximum speed.
-
Medium
-
The fan is running at 50-74% of its maximum speed.
-
Fast
-
The fan is running at 75-99% of its maximum speed.
-
Max
-
The fan is running at 100% of its maximum speed.
-
N/A
-
The fan is not installed.
-
- Speed
-
Indicates the relative speed of the fan based on the nominal speed range of the fan.
-
N/A
-
This value is not applicable to the 6100.
-
- Direction
-
The direction of airflow through the fan. Values are:
-
front-to-back
-
Air flows from the front of the system to the back of the system.
-
left-to-right
-
Air flows from the left of the system to the right of the system.
-
N/A
-
The fan is not installed.
-
- Status
-
Fan status. Values are:
-
uninitialized
-
The fan has not completed initialization.
-
ok
-
The fan is operating normally.
-
fault
-
The fan is in a fault state.
-
empty
-
The fan is not installed.
-
Examples
Showing output for systems with fan trays for 6100 switch series:
switch#show environment fanFan information --------------------------------------------------------------------------- Mbr/Fan Product Serial Number Speed Direction Status RPM Name --------------------------------------------------------------------------- 1/1 N/A N/A N/A left-to-right ok N/A
Showing output for a system without a fan tray:
switch#show environment fanFan information --------------------------------------------------------------- Fan Serial Number Speed Direction Status RPM --------------------------------------------------------------- 1 SGXXXXXXXXXX slow front-to-back ok 6000 2 SGXXXXXXXXXX normal front-to-back ok 8000 3 SGXXXXXXXXXX medium front-to-back ok 11000 4 SGXXXXXXXXXX fast front-to-back ok 14000 5 SGXXXXXXXXXX max front-to-back fault 16500 6 N/A N/A N/A empty ...