Resolved issuesfor 8320 Switchesin AOS-CX 10.06.0220
Category |
Bug ID |
Description |
RADIUS Port-Access |
229739 |
Symptom: RADIUS disconnect requests failed with the error CONTEXT_NOT_REMOVABLE. Scenario: This issue is related to timing, Configure concurrent onboarding enabled and default priority enabled. Thisissue occurs if a user issues a disconnect request for a client after MACauth is successfull, but dot1x authentication is still in-progress. Workaround: Avoid issuing a disconnect request until the highest priority authentication method is completed. Check theoutpt of theshow aaa authentication port-access interface all client-statuscommand to verify the both the auth-methods are complete. Disconnect the request once higher priority methods are complete. |
L3 addressing |
225356 |
Symptom: In some rare cases the switch will reboot or crash when a user issues theclear arp vrf Scenario: When theclear arp vrf |
Thermal Manager |
218536 |
Symptom: An SNMP trap is sent when a fan fails, but no event log is seen. Scenario: A single I2C read fails on a fan. Differences between the SNMP trap and the event log behaviors cause the SNMP trap to be sent, but not the event log. Workaround: Use the SNMP trap to determine if a fan has failed. |
OSPFv2 |
225988 |
Symptom: A mismatch occurs between the uptime shown in the output ofshow ospfcommands and the BGP state reflected the event log. Scenario: This issue occurs if no OSPF show commands are executed for 49 days or more Workaround: Run any OSPF show command once every 48 days or fewer. |
BGP |
226220 |
Symptom: A mismatch between uptime shown byshow bgpcommands and the BGP state is reflected in the event log. Scenario: This issue occurs if no BGP show commands were run for 49 days Workaround: Run any BGP show command once every 48 days or fewer. |
Credential Manager |
231199 |
Symptom: A password not applied after after a json config import if the user config contains a user password and an authorized key. Scenario:这个问题发生在配置containing a user account with both a password and an authorized key is applied and the running-config contains a different password for the same user. |